Chapter 7— IPL Command Reference
IPL Programmer’s Reference Manual 97
Emulation Mode, Enter
Purpose: Instructs the printer to operate in Emulation mode. The default is
Advanced Mode.
Syntax: <ESC>cn
where n specifies the dot size.
Printers:
Printer Default Values for n
All n = 0
0 = 10 mil (0.010 inch) dot size
1 = 15 mil (0.015 inch) dot size for bar codes only
(other fields are 10 mil)
Notes: Emulation mode lets you print bar code labels that were designed on an
86XX printer in multiples of 10 or 15 mil.
The field pointer designates the first field in format 0.
You disable the page select command and lose all previously host-entered
data.
Field, Select
Purpose: Selects a data field for entering or working with data.
Syntax: <ESC>Fn or <ESC>F”name”
where n is the number of the field.
Printers:
Printer Default Values for n Notes
All n = 0 0 to 199
All printers support this command the same
way.
Notes: The parameter for this command can either be the field number or the
field name, but not both. If neither is present, the printer defaults to 0.
If you use the field number, the printer enters all following data into field
n. If you use the field name, the printer enters all following data into all
fields with the specified name in the current format or page. You must
bracket the field name with quotation marks (“ ”).
The printer generates an error code (38) if you enter an invalid field
number.