Chapter 7— IPL Command Reference
IPL Programmer’s Reference Manual 189
Interpretive Field, Edit
Purpose: Edits an interpretive field.
Syntax: In
Printers:
Printer Default Values for n Notes
All n = 0 0 - 199
n is the field ID number of the bar code
field to be interpreted.
Notes: You cannot create interpretive fields with this command; you can only
create or delete them when enabling the interpretive of the corresponding
bar code field. The parameters for the default field are listed in the next
table.
Parameters for the Default Field
Parameter Syntax Default
Field origin o 2 dots below bar code, left justified
Field direction f 0 degrees
Character rotation r 0 degrees
Font c 7 x 9 standard
Height magnification h 2
Width magnification w 2
Pitch g Disabled
Point k Disabled
Border b Disabled
Data origin d Print mode
Data length 30
Each interpretive field is counted as an individual field in the maximum
number of 200 fields (0 – 199).