Chapter 7— IPL Command Reference
104 IPL Programmer’s Reference Manual
Format, Transmit (continued)
Notes: If you send <ESC>x to the printer without specifying a value for the n
parameter, the printer (except for the 3400A, 3400B, 3600, and 4400)
uploads the entire format directory. The directory appears in this format:
[IDnumber] [name] [type] [storage size]<CR><LF>
where:
IDnumber
is the format number that was specified by n in the
command that created the format.
name is the optional format name that may have been specified by
,name in the command that created the format.
type is 0 for formats.
storage size is the number of bytes needed to store the format.
The target printer remains in Advanced mode.
The printer generates an error code (25) if you enter an invalid number.
Increment and Decrement, Disable
Purpose: Resets any increment or decrement flags for the current field.
Syntax: <ESC>N